Calculated Moment Values
160901.6V5 = (B9 + B11 + B17) × ((B3 + B4_low) + (F9 + F10_low) + (J6 + J7_low) - (B6 + B7_low) - T3)
Low tolerance club moment calculation
160901.6R5 = (B9 + B16) × (B3 + F9 + J6 - B6 - R3)
Nominal club moment calculation
160901.6T5 = (B9 + B10_tol + B18) × ((B3 + B4_high) + (F9 + F10_high) + (J6 + J7_high) - (B6 - B7_high) - T3)
High tolerance club moment calculation
14754.62V4 = (F6 + F7_low) × ((F3 + F4_low) + (J6 + J7_low) - T3)
Low tolerance shaft moment calculation
14754.62R4 = F6 × (F3 + J6 - R3)
Nominal shaft moment calculation
14754.62T4 = (F6 + F7_high) × ((F3 + F4_high) + (J6 + J7_high) - T3)
High tolerance shaft moment calculation
13112.75V6 = (J3 + J4_high) × (T3 - (J9 + J10_low))
Low tolerance grip moment calculation
13112.75R6 = J3 × (R3 - J9)
Nominal grip moment calculation
13112.75T6 = (J3 + J4) × (T3 - (J9 + J10_high))
High tolerance grip moment calculation
534.55R7 = N3 × (F9 + J6 - B6 - R3)
Ferrule moment calculation
534.55R7 = N3 × (F9 + J6 - B6 - R3)
Ferrule moment calculation
534.55R7 = N3 × (F9 + J6 - B6 - R3)
Ferrule moment calculation
434.244R8 = N6 × (F9 - (B6/2) - R3)
Glue moment calculation
434.244R8 = N6 × (F9 - (B6/2) - R3)
Glue moment calculation
434.244R8 = N6 × (F9 - (B6/2) - R3)
Glue moment calculation
306.705R9 = N9 × ((10.5/2) × 25.4)
Tape moment calculation
306.705R9 = N9 × ((10.5/2) × 25.4)
Tape moment calculation
306.705R9 = N9 × ((10.5/2) × 25.4)
Tape moment calculation
0R10 = N12 × (F9 + J6 - B6 - R3)
Tip plug moment calculation
0R10 = N12 × (F9 + J6 - B6 - R3)
Tip plug moment calculation
0R10 = N12 × (F9 + J6 - B6 - R3)
Tip plug moment calculation
458.9583V10 = (V4 + V5 - V6 + R7 + R8 - R9) / V3
Low tolerance total moment value
458.9583R11 = (R4 + R5 - R6 + R7 + R8 - R9 + R10) / R3
Nominal total moment value
458.9583T10 = (T4 + T5 - T6 + R7 + R8 - R9) / T3
High tolerance total moment value
355.6V3 = B20 × 25.4
Fulcrum in millimeters
355.6R3 = B20 × 25.4
Fulcrum in millimeters
355.6T3 = B20 × 25.4
Fulcrum in millimeters
0.282023Slope = 0.282023
Constant slope value for swing weight calculation
0.282023Slope = 0.282023
Constant slope value for swing weight calculation
0.282023Slope = 0.282023
Constant slope value for swing weight calculation
-81.9622Intercept = -81.9622
Constant intercept value for swing weight calculation
-81.9622Intercept = -81.9622
Constant intercept value for swing weight calculation
-81.9622Intercept = -81.9622
Constant intercept value for swing weight calculation
D6.1B25 = CHAR((ROUND((V11-V12)/10,0)+64)) & V12
Low tolerance swing weight
D7.5B22 = CHAR((ROUND((R12-R13)/10,0)+64)) & R13
Nominal swing weight
D8.9B24 = CHAR((ROUND((T11-T12)/10,0)+64)) & T12
High tolerance swing weight